Knife Gate Valve

Knife Gate Valve

High Performance and Flexible Solutions

Our Knife Gate Valves, as the name suggests, feature a sharp, knife-shaped edge that provides excellent performance for abrasive or clogging-prone media such as powders, various slurries, pellets, pulp water, and sludge.
Depending on the type of fluid and application, we offer custom-designed specifications to meet your requirements — including bonnet types, dust covers, cleaning boxes, inspection ports, air purge systems, and double gland structures.

  • bonnet type

    bonnet type

  • open type

    open type

Production specification range

Flange ratingJIS 5K/10K、ANSI 150Lb and others
Size80mm~800mm
Maximum operating pressureMaximum differential pressure 0.49Mpa(5kgf/cm²)
Pressure testMain1.08Mpa(11kgf/cm²)
Seat0.19Mpa(2kgf/cm²)
Operating temperatureMetal seat400℃
Teflon seat200℃
EPDM seat100℃
NBR seat80℃
MaterialBodySCS13 and others
DiscSUS304 and others
RodSUS304 and others
SeatMetal(SCS13)、PTFE、EPDM、NBR
操作方式Manual (round handle) type, electric type, pneumatic type, hydraulic cylinder type and others
  • Please feel free to contact us in terms of special material as well as special specification.

Comparison of Gland Packing Structures

Rod seal (bonnet type)

Rod seal (bonnet type)

Spero Special Design

  • The bonnet structure enhances sealing performance.
  • The gland section requires only initial tightening — no frequent adjustments are needed.
  • With just two gland bolts, re-tightening (if ever required) is quick and simple.
  • Because only minimal gland compression is necessary, operating torque remains low.
  • Maintenance costs are reduced thanks to the compact packing design.

Disc seal (open type)

Disc seal (open type)

Standard Type

  • The open structure seals the gate itself, which tends to cause leakage from the corners and results in poor sealing performance.
  • Leakage is also likely to occur from the gland section, requiring periodic re-tightening.
  • With four gland bolts, it is difficult to achieve uniform tightening.
  • Since the gland must be tightened firmly to prevent leakage, operating torque is heavy.
  • Because the gate itself is sealed, maintenance costs are higher due to the larger packing size.